ANATOL VULCAN

(0)No Reviews yet
$0.00
SKU: ANA-VULCAN
DISPLAY NAME: ANATOL VULCAN
Prices starting at $ 23,800.00

Call for availability

Details

Vulcan

Series Gas Conveyor Dryers

Anatol’s Vulcan series gas conveyor dryers are the choice of textile printers who need efficiency and versatility. The Vulcan is designed to cure a variety of substrates decorated with screen printing, digital printing, and other printing methods. Its innovative air flow design, coupled with advanced technology, cures all types of ink with unprecedented reliability. The heat profile extends straight across the entire length of the heat chamber, eliminating the need for infrared boosting panels and ensuring a consistent temperature inside the dryer. The air recirculation system provides optimized airflow with improved spacing of forward-curved blades, exchanging the air inside the chamber 8 times every minute to draw moisture out of fabrics for fast curing. Air flow exhaust is adjustable within a range of 100-600 SCFM for maximum control. The Vulcanis built with safety in mind and features Anatol’s Chill Case air-cooling system that keeps the dryer’s exterior and control system cool all day. Anatol’s Chill Case uses forced air to keep heat inside the conveyor dryer and maintain a cool exterior. The Vulcan II provides all the benefits of the original Vulcan dryer on an industrial scale. The Vulcan II is available in twelve configurations, including three standard sizes, three high output arrangements, and three extra-large configurations, to meet the needs and space requirements of screen printing shops of all sizes.

Touchscreen Controls

·7” touchscreen control panel with intuitive Aries 2 operating system

·Program belt speed and temperature settings, service data, alarm list and more

·Programmable to retain 9 separate job settings

·Automatic shutdown sequence keeps the blower and belt running until the chamber cools

·A visible and audible warning is activated by an indicator light and buzzer when temperature is not within user-set parameters

·Touchscreen displays key operation information about heat chamber temperature, belt speed and other settings

·Program a schedule for the dryer to start up and shut down automatically at specified times on given days of the week

·View temperature plots to track temperature changes in real time

Heating System

·Fuzzy-logic digital controller ensures consistency by keeping within 1 degree of target temperature

·Solid-state gas system

·Maximum temperature of 450°F

·One burner per module

·Available for natural gas (NG) or liquid propane (LP)

·Exhaust dryer with flow adjustment range from 100-600 SCFM, allows for better exhaust gas control

Construction

·Efficient design provides a consistent and uniform temperature throughout the heating chamber

·Air-cooled cabinet located outside of the heating module ensures a long life for all electrical components

·Improved design allows for easy maintenance and lower operating costs

·Stainless steel slide-out filters

·Energy efficient heat exchange for incoming ambient air

·Double-wall construction with high-efficiency thermal insulation

·Exhaust hoods for the ends of the dryer

·Removable access panels for cleaning and maintenance

Belt

·Wide Teflon-coated fiberglass belt

·Heavy-duty conveyor rollers are crowned for better conveyor belt tracking

·Adjustable belt speed from a few feet up to 37.5 feet per minute

·Adjustable infeed/outfeed openings

·Digital belt speed readout

·Optional split belt on models with 48”+ belt widths


Specifications

Model #Belt WidthHeat Chamber LengthSmoke Hood LengthStandard Infeed/
Outfeed Length
Nominal Gas
Input Pressure
Electrical
Requirements
Exhaust diameterMaximum Burner CapacityOverall Dimensions
Length/Width/Height
Vul-36-0636″
92cm
6’0″
183cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 18 AMPS
3 Phase 208-240VAC, 3.57 kW, 10 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU17’0″/5’1″/6’6″
520cm/156cm/198см
Vul-36-8.536″
92cm
8’6″
259cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU19’6″/5’1″/6’6″
590cm/156cm/198cm
Vul-36-1036″
92cm
10’0″
305cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU21’0″/5’1″/6’6″
640cm/156cm/198cm
Vul-36-1236″
92cm
12’0″
366cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU23’0″/5’1″/6’6″
700cm/156cm/198cm
Vul-48-0648″
122cm
6’0″
183cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS.
10″
25cm
370,000 BTU17’0″/6’1″/6’6″
520cm/186cm/198cm
Vul-48-8.548″
122cm
8’6″
259cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU19’6″/6’1″/6’6″
590cm/186cm/198cm
Vul-48-1048″
122cm
10’0″
305cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU21’0″/6’1″/6’6″
640cm/186cm/198cm
Vul-48-10
Modular
48″
122cm
10’0″
305cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU21’0″/6’1″/6’6″
640cm/186cm/198cm
Vul-48-16
Modular
48″
122cm
16’0″
488cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU26’6″/6’1″/6’6″
800cm/186cm/198cm
Vul-60-1060″
152cm
10’0″
305cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU21’0″/7’7″/6’6″
640cm/231cm/198cm
Vul-60-12
Modular
60″
152cm
12’0″
366cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU22’6″/7’7″/6’6″
680cm/231cm/198cm
Vul-60-16
Modular
60″
152cm
16’0″
488cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU26’6″/7’7″/6’6″
800cm/231cm/198cm
Vul-60-20
Modular
60″
152cm
20’0″
609cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU30’6″/7’7″/6’7″
920cm/231cm/198cm
Vul-72-10
Modular
72″
182cm
10’0″
305cm
1’0″
30cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU21’0″/8’3″/6’6″
640cm/251cm/198cm
Vul-72-12
Modular
72″
182cm
12’0″
366cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU22’6″/8’3″/6’6″
680cm/251cm/198cm
Vul-72-16
Modular
72″
182cm
16’0″
488cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU26’6″/8’3″/6’6″
800cm/251cm/198cm
Vul-72-20
Modular
72″
182cm
20’0″
609cm
2’6″
76cm

5’0″ / 5’0″

150cm/150cm

4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 3.57 kW, 15 AMPS
3 Phase 208-240VAC, 3.57 kW, 9 AMPS
3 Phase 380-400VAC, 3.57 kW, 7 AMPS
10″
25cm
370,000 BTU30’6″/8’3″/6’6″
920cm/251cm/198cm
Model #Belt WidthHeat Chamber LengthOverall LengthSmoke Hood LengthStandard Infeed/
Outfeed Length
Nominal Gas
Input Pressure
Electrical
Requirements
Exhaust diameterMaximum Burner Capacity
Vul-60-24
High Output
60″
152cm
24’0″
732cm
34’5″
1590cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-60-28
High Output
60″
152cm
28’0″
854cm
38’5″
1712cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-60-32
High Output
60″
152cm
32’0″
975cm
42’5″
1834cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-60-36
High Output
60″
152cm
36’0″
1098cm
46’5″
1956cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-72-24
High Output
72″
182cm
24’0″
732cm
34’5″
1590cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-72-28
High Output
72″
182cm
28’0″
854cm
38’5″
1712cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-72-32
High Output
72″
182cm
32’0″
975cm
42’5″
1834cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
2 x 10″
2 x 25cm
2 x 370,000 BTU
Vul-72-36
High Output
72″
182cm
36’0″
1098cm
46’5″
1956cm
2’6″
76cm
5’0″ / 5’0″
150cm/150cm
4″-6″ W.C.
10-15cm W.C.
1 Phase 208-240VAC, 6.81 kW, 28 AMPS
3 Phase 208-240VAC, 6.81 kW, 18 AMPS
3 Phase 380-400VAC, 6.81 kW, 14 AMPS
10″
25cm
2 x 370,000 BTU


SKU
TDS
SDS
Brochure
Manual
ANA-VUL
Not Available
Not Available
Not Available
ANATOL VULCAN DRYER
Not Available
Not Available
Not Available

Ratings & Reviews

No reviews available

Be the first to Write a Review